REPAIR GARAGE VENTILATION - THE BUILDING CODE FORUM
Dec 29, 2014 What section in the 2009 IMC allows for CO detection to be the sole method to activate the required ventilation system in a 12,000 sf repair garage? Does 404.1 apply? This is not a parking garage, it is a repair garage. Is the system only required to run when CO detectors are activated? What... From bing.com
Apr 11, 2016 Parking garages, other than private garages, shall be classified as public parking garages and shall comply with the provisions of Sections 406.4.2 through 406.4.8 and shall be classified as either an open parking garage or an enclosed parking garage. From bing.com
S-1 OCCUPANCY, OCCUPANT LOAD | THE BUILDING CODE FORUM
Mar 15, 2022 2015 IBC, table 1004.1.2, what does a s-1 storage occupancy (repair garage with ordinary hazard) fall under for the occupant load factor? im thinking industrial at 200 sf per person From bing.com
Apr 27, 2021 How does a hole in the garage floor comply with this::: 406.3.3 Garage Floor Surfaces Garage floor surfaces shall be of approved noncombustible material. The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle entry doorway Click to expand... From bing.com
Nov 13, 2024 S-2 - motor vehicle parking garage. A golf cart is a small, motorized vehicle. Therefore, it falls under the literal definition posted in the IBC under S-2 occupancies. In fact, a modern automobile with a gas engine is hundreds of times more flammable than a golf cart. Also see IBC Section 406 If this is a motor vehicle repair garage see S-1 ... From bing.com
Apr 1, 2024 In the picture provided, I would say that is still a single portal frame opening. I think the intent was to prevent two portal frames immediately adjacent to each other using a common header. Example would be at the garage, where for example, multiple garage door openings are on the same wall plane and configured to use a common header over 2+ portal frames - that … From bing.com
VENTILATION SYSTEM FOR LUBE PIT - THE BUILDING CODE FORUM
May 23, 2019 Floor areas in major repair garage up to 18" AFF are considered classified, unless 4 ACH mechanical ventilation is provided and the vents for exhaust and makeup air are within 12" of the floor Ventilation must be continuous during occupied hours. [F] 502.15 Repair garages. Where Class I liquids or LP-gas are stored or used within a building having a basement or pit … From bing.com
PEX/PVC PIPES IN A GARAGE - THE BUILDING CODE FORUM
Jun 11, 2019 Are pex/ pvc water and waste lines allowed to run (exposed) through a garage? I know the code requires ducts to be min. 26 gage metal, and other penetrations between garage and house to be protected. From bing.com
S-1 MOTOR VEHICLE STORAGE VERSUS S-2 ENCLOSED PARKING GARAGE
Jan 12, 2023 Is the following facility an S-1 Storage or S-2 Parking Garage? 7,000 SF metal building - fully enclosed with garage doors and walk doors for access - for parking church vans (all smaller than commercial vehicles) in order to keep them safe when not in use. From bing.com