Hi all--I'm using the 2018 IBC, We have a 4 unit per floor, three story above podium apartment building with two exterior egress stairs. At a quick glance, I don't believe we can classify the … From bing.com
THRESHOLD FOR CONDO SLIDER - THE BUILDING CODE FORUM
Oct 16, 2009 Type B units are allowed to have an impervious balcony surface down 4 inches from the floor, but the threshold height is limited to 3/4 inch in 2009 A117.1 1004.5.2.2. From bing.com
Nov 27, 2019 Hi All, How can we calculate number of drain required per code for a balcony with 12" high parapet? Do we need overflow too? Thank you! From bing.com
CBC EXTERIOR 3RD FLOOR BALCONY EGRESS | THE BUILDING CODE FORUM
Oct 30, 2024 the balcony is 2224 sq ft. it is like a area, when the board member take a break during the meeting, can breath some fresh air, or if the board room holding an event, wine … From bing.com
Jan 25, 2019 Section 705.2 Cornices, eave overhangs, exterior balconies and similar projections extending beyond the exterior wall shall conform to the requirements of this section and … From bing.com
EGRESS BALCONIES IBC SECTION1021 - THE BUILDING CODE FORUM
Oct 27, 2009 Egress from a balcony is not similar to a sidewalk, since a balcony's egress is restricted to what the building provides. It is an outdoor area subject to Section 1004.5. If the … From bing.com
RECEPTACLES AT BALCONIES - THE BUILDING CODE FORUM
Jan 20, 2012 A balcony, deck or porch of a certain size requires a receptacle and many configurations below 20 sq. ft. must be included. That is not all inclusive. At a point, the size … From bing.com
AREA CALCULATION CLARIFICATION - THE BUILDING CODE FORUM
Oct 14, 2011 A balcony and the area beneath it would count, as the balcony is a projection of the floor. When I was in direct enforcement,I also would start with the outside dimensions and only … From bing.com
DECK, PORCH, PATIO, BALCONY? - THE BUILDING CODE FORUM
Nov 1, 2012 I am asking for your opinion about the various terms used in the IRC to describe exterior walking surfaces: Deck, Porch, Patio, Balcony. After 16 years of teaching deck codes … From bing.com
BALCONIES & MEZZANINES MEANS OF EGRESS - THE BUILDING CODE …
Oct 16, 2009 If we look at NFPA 101 we see the following verbiage. How does this differ from the IBC? 12.2.4.5 Balconies or mezzanines having an occupant load not exceeding 50 shall be … From bing.com
Are you curently on diet or you just want to control your food's nutritions, ingredients? We will help you find recipes by cooking method, nutrition, ingredients...